Press , use arrows to enter the factory default password ( 95 ), and press [SET] . You can now browse the complete configuration menu. Critical Parameter Configuration Table Parameter Function Default Value Recommended Range diF Temperature Compressor Differential (Hysteresis) 1.0°C to 4.0°C HSE Maximum limit settable for Setpoint Match maximum appliance limits LSE Minimum limit settable for Setpoint Match minimum appliance limits dit Interval time between two defrost cycles 4 to 8 hours dEt Maximum duration time for a defrost cycle 20 to 45 minutes dSt Defrost termination temperature (via Probe 2) 4.0°C to 12.0°C FSt Fan stop temperature threshold -2.0°C to 8.0°C FAt Evaporator fan activity delay after defrost 1 to 5 minutes OdO Delay time for outputs upon machine power-up 1 to 3 minutes for safety Defrost Modes and Fan Management

The Eliwell SB655 C manual provides detailed information on the device's key features, including:

Evaporator defrost temperature probe (Probe 2 / Pb2).

Indicates the compressor is active. If flashing, it means a delay timer is running. Fan Icon: Indicates the evaporator fans are running.

Prevents end-users from setting the target temperature too high. Minimum Setpoint Limit -55°C to HSE

, 50/60Hz (or 12Vac/dc depending on the specific model variant).

The Eliwell SB655 C relies on specific parameter codes to govern refrigeration behavior. Below are the most critical configurations for standard installations. Regulation Parameters ( r Menu)

The maximum duration allowed for a single defrost cycle. This acts as a safety timeout. Fan Management ( F Menu)

TYPICAL WIRING SCHEMATIC (Example Only) +---------------------------------------+ | 1 2 | 3 4 | 5 6 | 7 8 | 9 10 11 12| +---+--+---+--+---+--+---+--+-----+-----+ | | | | | | POWER COMP DEF FAN PROBE1 | INPUT RELAY RELAY RELAY (AMB) PROBE2 (DEF) Installation Steps Cut out a standard