Programat P90 Manual Fixed: Ivoclar
The most common cause of vacuum loss is debris on the sealing surfaces. Turn off the furnace and let it cool completely. Open the firing chamber.
If the head fails to open, close, or stop properly, it may cause damage to the heating element or the work in progress.
Wipe the O-ring and the corresponding upper sealing flange with a lint-free microfiber cloth moistened with isopropyl alcohol. Debris, lint, or investment dust here will prevent a tight seal. Apply a microscopic film of high-vacuum silicone grease if the rubber appears dry. Step 3: Test the Vacuum Release Valve
The P90 relies on a tactile keypad and an LED display. Understanding the basic navigation is the first step to ensuring high-quality ceramic restorations. Basic Firing Setup: ivoclar programat p90 manual fixed
Turn the power switch back on. If an error code persists immediately upon boot-up, consult your manual's error code index to identify whether it indicates a specific board failure or a blown internal fuse.
If your ceramic shades are consistently coming out too chalky (under-fired) or rounded and shiny (over-fired), your thermocouple requires manual calibration using the classic silver wire test. Step 1: Prepare the Calibration Matrix
Power On: Use the main switch located at the rear or side of the base. The most common cause of vacuum loss is
to blow out dust from the chamber; the structural insulation utilizes ceramic fibers that must not be atomized into the breathing environment.
The Fix: Check the O-ring on the firing table. Clean it with a lint-free cloth and apply a tiny amount of high-temp vacuum grease. Ensure the vacuum pump hose is not cracked or kinked.
: Houses the numeric membrane keyboard, the primary O/I mains switch with a built-in pilot lamp, and the 7-segment parameters display window. If the head fails to open, close, or
Take a 20mm piece of pure silver wire. Bend it into a bridge or U-shape over the designated tabs on your calibration tray. Ensure the center of the wire suspends freely without touching the base of the tray.
This guide is for informational purposes. Always refer to the official Ivoclar Vivadent Programat P90 manual before performing any electrical or mechanical repairs. Opening the furnace voids warranty if done by unauthorized personnel.