User Manual: Micronova Es99

: Manages automatic start/stop cycles, pressure regulation, and idle (unloaded) running periods to optimize energy efficiency.

: Manages automatic start/stop cycles and loading/unloading based on air consumption. micronova es99 user manual

All electrical connections terminate at the main controller circuit board. Always disconnect the main power supply before servicing the terminal blocks. Terminal Pin Connection Component Electrical Characteristics Main AC Power Supply 230 V AC Input FUMI Exhaust Gas Extractor Fan 230 V AC Triac Control ARIA Ambient Room Air Fan 230 V AC Triac Control COCH Auger Gear Motor (Pellet Feed) 230 V AC Relay Output ACC Ignition Spark Plug/Heater Element 230 V AC Relay Output ALC / SFT Safety Vacuum / High-Limit Thermostat Low Voltage Dry Contact (NC) SOND FUMI Exhaust Gas Temperature Sensor Type J/K Thermocouple Input SOND ARIA Ambient Room Temperature Sensor NTC 10k Ohm Thermistor Input ENCODER Exhaust Fan Speed Sensor 3-Wire TTL Signal Input (Optional) 4. Parameter Programming (Technical Menu) Always disconnect the main power supply before servicing

Note: Modifying these settings can affect the safety of your stove. Adjust exhaust and convection fan speeds. Auger Times: Fine-tune the feed rate for specific pellets. Sensor Calibration: Calibrate temperature readings. 5. Troubleshooting the Micronova ES99 (Alarm Codes) Adjust exhaust and convection fan speeds